/ / / Oscillation gas meters Pulsar

Oscillation gas meters Pulsar

Price on request

Скидка предоставляется на оптовые партии при указании адреса объекта

Купить оптом

Description

They are designed to measure the volume of natural gas, liquefied gas vapors, and other non-aggressive gases. The principle of operation is based on the dependence of oscillation frequency to measure gas flow rate. The oscillations of the flow are converted by a piezoelectric element into an electric pulse proportional to the volume of gas. This signal is then converted in the electronic unit into the value of the gas volume and recorded as total.

Available according to EN 1359.

  • High reliability due to the absence of moving parts
  • Available with temperature correction
  • Affordable price
  • Ease of installation using flexible hosepipes
  • Digital filter protects against vibrations and external interference
Nominal DN 15; 20
Standard size 1,6; 2,5; 3,2; 4
Minimum flow rate, qi, m3/h 0,038; 0,04
Maximum flow rate, qs, m3/h 1,6; 2,5; 3,2; 4
Fitting thread, inch/flange size 1/2"; 3/4"
Limits of permissible relative error in measuring gas volume under operating conditions or reduced to normal conditions according to GOST 2939-63 for temperature, %, in the range of volumetric flow rat
— Qmin ≤ Q < 0,2·Qmax ±2,5
— 0,2·Qmax ≤ Q ≤ Qmax ±1,5
Maximum operating excess gas pressure, Pmax, kPa 5
Loss of gas pressure at Qmax, kPa, no more 1,5
Ambient and working temperature, °C -10 …+ 50
Interverification interval, years 6
Battery life, years, not less 6
Average service life, year 12